SlabTank by QPOD

Integrated Stormwater Storage Within Your Foundation

Designed to manage stormwater where space is limited, SlabTank integrates water storage directly beneath slabs, driveways, and hardstand areas, reducing the need for separate tanks and simplifying site design.

 

SlabTank by QPOD

CodeMark certified.

CodeMark certified, making design, approval, and specification straightforward.

 

What is SlabTank™?

SlabTank™ is a CodeMark-certified modular stormwater detention system designed to sit beneath slabs, driveways, and other hardstand areas, allowing you to store and manage water within space that already exists on site.

Instead of adding separate tanks, SlabTank integrates directly into your build, helping simplify layouts while supporting compliant stormwater design.

Built for flexibility, SlabTank is a natural fit for in-slab installation, but works just as effectively under driveways, patios, and decks.

The system uses a lightweight, modular design that fits within standard formwork without requiring special footings or complex installation. With two standard sizes (630L at 220mm high and 850L at 300mm high), it adapts easily across a wide range of applications.

Its flat profile aligns with typical raft slab modules (approx. 1100mm width) and integrates cleanly with reinforcing steel and plumbing during setup.

With no interconnections required between tanks, SlabTank simplifies plumbing, reduces potential leak points, and allows flexible placement even in more challenging ground conditions.

SlabTank came from years of conversations with builders and designers who were uneasy about what was happening inside their slabs. Interconnections, penetrations, the risk of leakage. It all added complexity and doubt. With QPOD, we had already rethought what sits within the slab. SlabTank was the natural next step. A way to simplify in-slab water attenuation and remove the uncertainty around interconnections.

Peter Crawshaw

General Manager, QPOD Earth-Friendly Foundations

Why SlabTank?

Stormwater usually ends up dictating parts of a design. Tank locations, pipe runs, lost space. SlabTank flips that around by working within the footprint you already have.

  • Makes use of existing space
    Integrates storage beneath slabs, driveways, and hardstand areas instead of carving out room elsewhere on site.

  • Simplifies site planning
    Reduces the need for separate tanks, helping keep layouts cleaner and easier to coordinate.

  • Straightforward to install
    Modular units drop into standard formwork and can be set out alongside reinforcing and services.

  • Flexible across different projects
    CodeMark cerified and suitable for residential builds, including sites where space is tight or irregular.

  • Built for long-term use
    Designed to sit within the structure, protected from exposure and aligned with the lifespan of the build.

How SlabTank Works On Site

Some water attenuation solutions mean extra trades, extra time, and extra things to coordinate. SlabTank doesn’t.

It goes in with the slab — positioned in the formwork, connected with standard PVC fittings, and concreted over as part of your normal pour sequence. No separate excavation. No need for an approved installer. No additional time beyond what you’re already spending on the foundation.

You Can Install It

Unlike competing systems that require accredited or approved installers, SlabTank can be installed by any registered builder or concretor. The skills are already on site. The process fits within what your team is already doing.

One Large Tank. Not Dozens of Small Ones.

Traditional modular detention systems can mean managing, connecting, and testing a large number of small cells or chambers. SlabTank units are large — 630L or 850L each — so you reach your required detention volume with far fewer units, a simpler layout, and significantly less pipework to deal with on site.

Pressure Tested Before It Arrives

By the time SlabTank reaches your site, the testing is already done. Each unit is pressure tested at the point of manufacture — so there’s nothing to verify, certify, or sign off on site before the concrete goes in.

No Interconnections

Each SlabTank module works independently, so there’s no need to link tanks together.

That removes a common failure point and anxiety, simplifies installation, and gives you more flexibility with layout. Tanks can be positioned where they’re needed, even in tighter or irregular spaces, without redesigning the system around connections.

Less plumbing. Less risk. Easier to get right on site.

Low Profile/Large Volume

Big storage, minimal height.

SlabTank is designed to sit within standard slab depths while still delivering the volume required for stormwater attenuation — without pushing the rest of the design around it.

Two Size Solutions

Two tank depths available: 220mm (630L) and 300mm (850L)

Ready For Anything

Designed for New Zealand sites, SlabTank is suitable across TC1, TC2 and TC3 ground conditions.

It works alongside standard foundation detailing, giving you a practical way to incorporate stormwater attenuation without overcomplicating the design.

Designed for Strength

Built off the QPOD platform, SlabTank is made from MDPE uses the same structural leg design proven in slab foundations across New Zealand.

It’s engineered to carry load where it matters, so it integrates cleanly under slabs, driveways, and other load-bearing areas without introducing weak points into the system.

CodeMark Certified

SlabTank is CodeMark certified, providing a recognised pathway to compliance under the New Zealand Building Code.

It gives designers and builders confidence that the system has been independently assessed and can be specified with clarity across projects.

Design and Technical Overview

SlabTank integrates stormwater storage directly beneath your slab, driveway, or subfloor using a modular, no-interconnection system.

  • Modular units placed within slab footprint

  • Connected to a central distribution chamber

  • Stores and controls stormwater at source

  • No separate tanks or remote systems required

  • Designed to work alongside QPOD or standalone

 

 

 

Two configurations give flexibility depending on slab height and storage requirements.

  • Length: 3290mm

  • Width: 1090mm

  • Height options: 220mm / 300mm

  • Storage: 630L / 850L per unit

Installed as part of the slab process. No separate tank install required.

 

SlabTank integrates directly within a standard TC2 slab, providing on-site stormwater storage without changing the way the slab is built.

SlabTank can be installed beneath driveways and hardstand areas, turning otherwise unused space into functional stormwater storage.

SlabTank can be used beneath suspended floors or pile systems, providing stormwater storage without interfering with structural elements.

Calculate Your Water Attenuation

Stormwater attenuation is simply the amount of water your site needs to temporarily store before it’s released.

Start by entering your required volume (in litres), typically provided by your engineer or council. The calculator will then work out how many SlabTank units are needed to meet that requirement, along with the total footprint under your slab.

In the SlabTank Stormwater Attenuation Calculator you can choose between 630L or 850L tanks, or a combination of both depending on your layout and depth constraints. Each tank shares the same footprint, so the system scales cleanly across your slab.

SlabTank Stormwater Attenuation Calculator

Rainwater, Handled On Autopilot

SlabTank manages what happens below the slab.
RainHarvester takes care of what happens next.

The SlabTank RainHarvester Auto is an optional a fully automatic system that draws rainwater from your tank and supplies it to your home or site, switching to mains when needed and back again when levels recover.

It prioritises rainwater first, using what you’ve already captured, and only brings in mains supply when it’s required to maintain consistent pressure and flow across the home.

No manual changeovers.
No monitoring tank levels.
No interruption to supply.

When tank levels drop, the system responds automatically, maintaining service without the user needing to step in or even notice. When the tank refills, it switches back, returning to rainwater as the primary source.

This removes the usual complexity around rainwater systems, where multiple components, manual switching, or uncertainty can creep into the setup.

It’s designed to pair directly with SlabTank, creating a complete solution from storage through to supply. One system that manages water where it’s stored, and how it’s used, without adding extra layers to design, installation, or operation.

Get Started With SlabTank

Want A CodeMark Certified Solution?

Save Time, Save Money. QPOD™ CodeMark™ Certification

QPOD is a CodeMark™ certified solution. What are the benefits in CodeMark™ certification when it comes to QPOD™, well it means cost savings including less concrete, less steel, no engineering. It also means a streamlined approval process and your choice of concrete.

TALK TO A QPOD REP

0800 55 33 00